Criteria for indirect measurements in M-S testing
Álvaro Gómez‐Pau, Luz María Balado Suárez, Joan Figueras Pàmies · RECERCAT (Consorci de Serveis Universitaris de Catalunya) · 2014
Analog and mixed-signal circuit testing is a cballenging task demanding large amounts of resources. In order to battle against this drawback, alternate testing has been established as an eflicient way of testing analog and M-S circuits by using indirect measures instead of the classic specification based testing. In this work we propose the use of Kendall's Tau rank correlation coeflicient for rating the suitability of a set of candidate indirect measures to be used in mixed-signal testing. Such criterion is shown to be adequate since it allows to avoid or minimize information redundancy in the measures set. As a proof of concept, a 4th order band-pass Butterworth filter has been simulated under the presence of process variations. The circuit has been tested using a subset of measures selected according to minimum Kendall's Tau coeflicient. Analog test efliciency metrics are reported showing test misclassification rate is among the best 15% possible, therefore validating the proposal.