Large diameter cone penetrometers: What is an appropriate location for the transition to the rod diameter?

D.A. de Lange, T.A. van Duinen, D.J. Peters · 2022

15 cm 2 cone penetrometers are typically pushed to depth by means of 10 cm 2 rods. Therefore, a transition in diameter will be present at a certain distance from the cone shoulder. Although the standards give a requirement for the position of this transition, cone penetrometer configurations that don’t meet this requirement are often preferred by CPT sounding companies and are being used in practice. This raises a dilemma. In order to fuel discussion, a first step was made by performing two series of 9 CPTs with different penetrometer geometries. The effects of the penetrometer designs on the measured quantities were investigated. From a preliminary analysis of the results no systematical differences between the different penetrometers were observed. When these preliminary findings are better understood and validated, the standards can be updated.

Read the paper · More papers on PaperTik