System Analysis for Receiving Performance Improvement of Mobile Station in PCS

Jae-Han Ju, Se-Seung Park, Jong-An Park, Jong-Hun Cheon · The Transactions of the Korea Information Processing Society · 1999

In this paper, we examined noise figure and the 3rd order intercept point in sensitivity single tone desensitization, and response attenuation by intermodulation spurious of receiver and also analyzed them through simulation based on J-STD-0.18, which is the minimum specification of PCS mobile station. The result of simulation was as follows ; In sensitivity specification, the total noise figure was 5.99dB and the 3rd order intercept point was -33.979dB. Ins ingle tone desensitization and intermodulation spurious response attenuation specification, the total noise figure was 6.375dB and the 3rd order intercept point was -26.99dBm. When there is an interference tone, the nosie figure and the 3rd order intercept point have been increasedly 0.367dB respectively, compared wit that of no interference tone. Because the amount of increase in the 3rd order intercept point was highly raised more than that of noise figure, mixer, closely related to interference tone should be specified in high 3rd order intercept point. At a frequency spacing of 1.25MHz and 2.05MHz from center frequency in IF SAW filter, attenuation should be more than 45dB.