Analysis and Comparison of Transformer between Common Half-bridge Circuit and Half-bridge Series Resonant Circuit
Qin Wang · IEEE Transactions on Power Electronics · 2005
Based on the comparison and analysis of the model between the common half-bridge circuit and the half-bridge series resonant circuit,the working character of transformer in two circuit have been concluded;and the design methods of main parameters such as primary voltage,the primary number of turns,the turn-ratio of transformer in the two circuit have been completely discussed.At last,the paper analyses the cause that the half-bridge series resonant circuit uses voltage-bridge doubled circuit but did not lead to double the voltage.