Method for control data synchronization of business modules in a stack system(Chinese)
WU Helan, HU Bingyuan, Chen Biduo · Huadong Shifan Daxue xuebao. Ziran kexue ban · 2008
This paper defined a set of architectural and modeling to send data from stack master equipment to stack slave equipment in regular sequence in a stack system,to achieve graceful re- start and non-stop forwarding.A method for batch data synchronization was presented,with the help of message channel detection and sequence number confirmation,it can improve the efficien- cy and reliability.The running results showed that this architectural and modeling totally saris fled the design requirements of non-stop forwarding.