Stability and accuracy of active shielding for grounded capacitive sensors
Ferran Reverter, Xiujun Li, G.C.M. Meijer · Measurement Science and Technology · 2006
Active shielding is commonly used to measure remote grounded capacitive sensors because it reduces the effects of both external noise/interference and parasitic capacitances of the shielded cable. However, due to active shielding, the measurement circuit can become unstable and inaccurate. This paper analyses these limitations theoretically and experimentally, and then provides guidelines for improving the performance of active shielding. One of the key points is the selection of the bandwidth of the amplifier that drives the shield of the coaxial cable. A wide bandwidth improves accuracy, but a narrow bandwidth improves stability. Therefore, there is a trade-off between stability and accuracy with respect to the bandwidth of the amplifier.