Accurate detection of 3D tubular tree structures
Nicolas Flasque, Michel Desvignes, Jean‐Marc Constans, Marinette Revenu · 2002
The spatial resolution of Magnetic Resonance Angiography (MRA) makes it a powerful tool for diagnosis and surgical planning. However, image interpretation and visualization tools are missing, and three-dimensional measurements are not usually accessible. Flexible visualization of the whole vascular tree and precise quantification of phenomena like carotid stenosis are applications of an automated processing of MRA. Building an accurate model of a tubular objects network such as bronchi or blood vessels can provide a substantial help for 3D visualization and quantification. The authors present a tracking algorithm of centrelines that makes very few assumptions on the structure grey-level profile. The main originality of this work is the accurate 3D centreline tracking process which provides subvoxel accuracy and deals with bifurcations. This approach has been successfully applied to the cerebral vasculature in MRA images.