Safely Stimulating the Clock Synchronization Algorithm in Time-Triggered Systems–A Combined Formal and Experimental Approach

Matthias Függer, Eric Armengaud, Andreas Steininger · IEEE Transactions on Industrial Informatics · 2009

Deterministic replay is used during testing to reproduce a scenario and drive the system under test to a given state. In this work, we replay ana prioridefined bus traffic to influence the clock synchronization mechanism. Beyond testing this distributed mechanism itself, our aim is to draw conclusions on the nodes' bus receiver operation. Since these replay activities are part of a transparent online test procedure, it is important to ensure that they do not represent a threat for proper system operation. We show this for TTP/C by means of a generic formal proof, while for the case of FlexRay we formally prove that the system precision can be bounded according to the replay operation applied. Experimental results confirm and illustrate our approach.

Read the paper · More papers on PaperTik