Comparison of Trend Detection Algorithms in the Analysis of Physiological Time-Series Data

William Melek, Z. Lu, A. Kapps, W.D. Fraser · IEEE Transactions on Biomedical Engineering · 2005

This paper presents a comparative performance analysis of various trend detection methods developed using fuzzy logic, statistical, regression, and wavelet techniques. The main contribution of this paper is the introduction of a new method that uses noise rejection fuzzy clustering to enhance the performance of trend detection methodologies. Furthermore, another contribution of this work is a comparative investigation that produced systematic guidelines for the selection of a proper trend detection method for different application requirements. Examples of representative physiological variables considered in this paper to examine the trend detection algorithms are: 1) blood pressure signals (diastolic and systolic); and 2) heartbeat rate based on RR intervals of electrocardiography signal. Furthermore, synthetic physiological data intentionally contaminated with various types of real-life noise has been generated and used to test the performance of trend detection methods and develop noise-insensitive trend-detection algorithms.

Read the paper · More papers on PaperTik