Editing wild points in isolation - Fast agreement for reliable systems (Preliminary version)
Phil Kearns, CAROL EVANS · 7th Computers in Aerospace Conference · 1989
Consideration is given to the intuitively appealing notion of discarding sensor values which are strongly suspected of being erroneous in a modified approximate agreement protocol. Approximate agreement with editing imposes a time bound upon the convergence of the protocol - no such bound was possible for the original approximate agreement protocol. This new approach is potentially useful in the construction of asynchronous fault tolerant systems. The main result is that a wild-point replacement technique called t-worst editing can be shown to guarantee convergence of the approximate agreement protocol to a valid agreement value. Results are presented for a four-processor synchronous system in which a single processor may be faulty.