Measurement of Permittivity of Substances Using the Partially Filled Cavity Method
S. V. Bukharov · Telecommunications and Radio Engineering · 2006
Method of complex permittivity measurement by partially filled resonator is considered. The simplest model (transcendental equation) is used. Curves of H111- and H011- in dependence on sample permittivity and infill level are obtained.