Dynamic modeling of a supercritical helium closed loop with the 4C code

R. Zanino, R. Bonifetto, Laura Savoldi, Francesco Casella · AIP conference proceedings · 2012

A new Modelica library has been developed, which provides the framework for the drag-and-drop cryogenic circuit modeling capability of the Cryogenic Circuit Conductor and Coil (4C) code.The code has been applied to the simulation of a thermal-hydraulic transient in a closed supercritical helium (SHe) loop, driven by a pulsed heat load and including multiple feedback controls.The 4C results are in good qualitative agreement with those of the Vincenta code.