Diagnosabilities of exchanged hypercube networks under the pessimistic one-step diagnosis strategy
Jiarong Liang, Ying Huang, Liang-Cheng Ye · Journal of Systems Engineering and Electronics · 2015
The exchanged hypercube EH(s, t) (where s 1 and t 1) is obtained by systematically reducing links from a regular hypercube Qs+t+1. One-step diagnosis of exchanged hypercubes which involves only one testing phase during which processors test each other is discussed. The diagnosabilities of exchanged hypercubes are studied by using the pessimistic one-step diagnosis strategy under two kinds of diagnosis models: the PMC model and the M M∗ model. The main results presented here are the two proofs that the degree of diagnosability of the EH(s, t) under pessimistic one-step t1/t1 fault diagnosis strategy is 2s where 1 s t (respectively, 2t, where 1 t s) based on the PMC model and that it is also 2s where 1 s t (respectively, 2t, where 1 t s) based on the M M∗ model.